Single shaft gas turbine.

Attributes

NameTypeDescription
atPUAmbient temperature load limit (<i>Load Limit</i>). Typical value = 1.
dturbPUTurbine damping factor (<i>Dturb</i>). Typical value = 0,18.
ktPUTemperature limiter gain (<i>Kt</i>). Typical value = 3.
mwbaseActivePowerBase for power values (<i>MWbase</i>) (> 0). Unit = MW.
rPUPermanent droop (<i>R</i>) (>0). Typical value = 0,04.
t1SecondsGovernor mechanism time constant (<i>T1</i>) (>= 0). <i>T1</i> represents the natural valve positioning time constant of the governor for small disturbances, as seen when rate limiting is not in effect. Typical value = 0,5.
t2SecondsTurbine power time constant (<i>T2</i>) (>= 0). <i>T2</i> represents delay due to internal energy storage of the gas turbine engine. <i>T2</i> can be used to give a rough approximation to the delay associated with acceleration of the compressor spool of a multi-shaft engine, or with the compressibility of gas in the plenum of a free power turbine of an aero-derivative unit, for example. Typical value = 0,5.
t3SecondsTurbine exhaust temperature time constant (<i>T3</i>) (>= 0). Typical value = 3.
vmaxPUMaximum turbine power, PU of MWbase (<i>Vmax</i>) (> GovGAST.vmin). Typical value = 1.
vminPUMinimum turbine power, PU of MWbase (<i>Vmin</i>) (< GovGAST.vmax). Typical value = 0.