Different from LimIEEEOEL, LimOEL2 has a fixed pickup threshold and reduces the excitation set-point by means of a non-windup integral regulator. <i>Irated</i> is the rated machine excitation current (calculated from nameplate conditions: <i>V</i><i><sub>nom</sub></i>, <i>P</i><i><sub>nom</sub></i>, <i>CosPhi</i><i><sub>nom</sub></i>).

Attributes

NameTypeDescription
ifdlimPULimit value of rated field current (<i>I</i><i><sub>FDLIM</sub></i>). Typical value = 1,05.
koiPUGain Over excitation limiter (<i>K</i><i><sub>OI</sub></i>). Typical value = 0,1.
voimaxPUMaximum error signal (<i>V</i><i><sub>OIMAX</sub></i>) (> OverexcLim2.voimin). Typical value = 0.
voiminPUMinimum error signal (<i>V</i><i><sub>OIMIN</sub></i>) (< OverexcLim2.voimax). Typical value = -9999.