ConductingEquipment

Class Description

The parts of the AC power system that are designed to carry current or that are conductively connected through terminals.

Attributes

None

Relationships

Ancestors

Descendents

Associations

Source ClassSource CardinalityTargetTarget CardinalitySource NameSource Assoc. DescriptionTarget NameTarget Assoc. Description
ConductingEquipment1ProtectiveActionAdjustment0..*ConductingEquipmentConductingEquipment whose operating condition is changed when this protective action adjustment gets activated.ProtectiveActionAdjustmentThe operating condition to the Conducting Equipment is changed when protective action adjustment is activated. For ShuntCompensator or other conducting equipment that operates on discrete values (integer), the values given in float will be rounded.
ConductingEquipment1SvStatus0..*ConductingEquipmentThe conducting equipment associated with the status state variable.SvStatusThe status state variable associated with this conducting equipment.
ConductingEquipment0..*ProtectionEquipment0..*ConductingEquipmentsProtection equipment may be used to protect specific conducting equipment.ProtectionEquipmentsProtection equipment used to protect specific conducting equipment.
ConductingEquipment0..*BaseVoltage0..1ConductingEquipmentAll conducting equipment with this base voltage. Use only when there is no voltage level container used and only one base voltage applies. For example, not used for transformers.BaseVoltageBase voltage of this conducting equipment. Use only when there is no voltage level container used and only one base voltage applies. For example, not used for transformers.
ConductingEquipment1Terminal0..*ConductingEquipmentThe conducting equipment of the terminal. Conducting equipment have terminals that may be connected to other conducting equipment terminals via connectivity nodes or topological nodes.TerminalsConducting equipment have terminals that may be connected to other conducting equipment terminals via connectivity nodes or topological nodes.
ConductingEquipment0..*JumperAction0..1JumpedEquipmentsConducting equipment is affected when the jumper action connects one or both ends of a jumper to the conducting equipment. If the jumper action involves placing one or both ends of a jumper anywhere along a line segment, you must use the clamp (to get the distance from one terminal), using the explicit relation with clamp. In the case of placing one or both ends of the jumper at a line segment terminal, reference to one or more line segments is sufficient.JumpingActionJumper action involving jumping operation on this conducting equipment.
ConductingEquipment0..1GroundAction0..1GroundedEquipmentEquipment being grounded with this operation. In case of placing a ground anywhere along a line segment, you must use the clamp (to get the distance from one terminal), so use the explicit relation with line segment. In all other cases (including placing the ground at a line segment terminal), reference to one or more conducting equipment is sufficient.GroundingActionAction involving grounding operation on this conducting equipment.
ConductingEquipment0..*Outage0..1OutageIsolationEquipmentOutage