MeasurementKind

Class Description

Kind of read / measured value.

Attributes

NameTypeDescription
alarm
apTitle
apparentPowerFactor
applicationContext
assetNumber
audibleVolumeSound
bandwidth
batteryCarryover
batteryVoltage
billCarryoverCustomer’s bill for the (Currency)
billLastPeriodCustomer’s bill for the previous billing period (Currency)
billToDateCustomer’s bill, as known thus far within the present billing period (Currency)
broadcastAddress
connectionFeeMonthly fee for connection to commodity.
currencyfunds
current
currentAngle
currentImbalance
dataOverflowAlarm
date
demand
demandLimit
demandResetUsually expressed as a count as part of a billing cycle
deviceAddressType1
deviceAddressType2
deviceAddressType3
deviceAddressType4
deviceClass
diagnostic
distance
distortionPowerFactor
distortionVoltAmp
electronicSerialNumber
emergencyLimit
encoderTamper
endDeviceID
energization
energizationLoadSide
energy
fan
frequency
frequencyExcursionUsually expressed as a “count”
fundDup with “currency”
groupAddressType1
groupAddressType2
groupAddressType3
groupAddressType4
ieee1366ASAI
ieee1366ASIDI
ieee1366ASIFI
ieee1366CAIDI
ieee1366CAIFI
ieee1366CEMIn
ieee1366CEMSMIn
ieee1366CTAIDI
ieee1366MAIFI
ieee1366MAIFIe
ieee1366MomentaryInterruption
ieee1366MomentaryInterruptionEvent
ieee1366SAIDI
ieee1366SAIFI
ieee1366SustainedInterruption
interruptionBehaviour
inversionTamper
ipAddress
lineLoss
loadInterrupt
loadShed
loss
macAddress
maintenance
mfgAssignedConfigurationID
mfgAssignedPhysicalSerialNumber
mfgAssignedProductNumber
mfgAssignedUniqueCommunicationAddress
multiCastAddress
negativeSequence
noneNot Applicable
oneWayAddress
phasorPowerFactor
phasorReactivePower
physicalTamper
positiveSequence
power
powerFactor
powerLossTamper
powerOutage
powerQuality
powerRestoration
programmed
pushbutton
quantityPower
relayActivation
relayCycleUsually expressed as a count
removalTamper
reprogrammingTamper
reverseRotationTamper
sagor Voltage Dip
signalStrength
signaltoNoiseRatioMoved here from Attribute #9 UOM
swell
switchArmed
switchDisabled
switchPosition
tamper
tapPosition
tariffRate
temperature
totalHarmonicDistortion
transformerLoss
twoWayAddress
unipedeVoltageDip10to15
unipedeVoltageDip15to30
unipedeVoltageDip30to60
unipedeVoltageDip60to90
unipedeVoltageDip90to100
voltage
voltageAngle
voltageExcursion
voltageImbalance
volumeClarified from Ed. 1. to indicate fluid volume
volumetricFlow
watchdogTimeout
zeroFlowDuration
zeroSequence