DeviceStatus
Class Description
Status of device
Attributes
| Name | Type | Description |
|---|---|---|
| changedTime | TimeType | The time at which the reported values were recorded. |
| onCount | UInt16 | The number of times that the device has been turned on: Count of "device on" times, since the last time the counter was reset |
| opState | UInt8 | Device operational state: 0 - Not applicable / Unknown 1 - Not operating 2 - Operating 3 - Starting up 4 - Shutting down 5 - At disconnect level 6 - kW ramping 7 - kVar ramping |
| opTime | UInt32 | Total time device has operated: re-settable: Accumulated time in seconds since the last time the counter was reset. |
| pollRate | UInt32 | The default polling rate for this function set (this resource and all resources below), in seconds. If not specified, a default of 900 seconds (15 minutes) is used. It is RECOMMENDED a client poll the resources of this function set every pollRate seconds. |
Relationships
Inherits from
Descendant classes
- No descendant classes
Associations
| Source Class | Cardinality Source | Target Class | Cardinality Target |
|---|---|---|---|
| DeviceStatus | Temperature | 0..* | |
| DeviceStatus | TimeLink | 0..1 |