DeviceStatus

Class Description

Status of device

Attributes

NameTypeDescription
changedTimeTimeTypeThe time at which the reported values were recorded.
onCountUInt16The number of times that the device has been turned on: Count of "device on" times, since the last time the counter was reset
opStateUInt8Device operational state: 0 - Not applicable / Unknown 1 - Not operating 2 - Operating 3 - Starting up 4 - Shutting down 5 - At disconnect level 6 - kW ramping 7 - kVar ramping
opTimeUInt32Total time device has operated: re-settable: Accumulated time in seconds since the last time the counter was reset.
pollRateUInt32The default polling rate for this function set (this resource and all resources below), in seconds. If not specified, a default of 900 seconds (15 minutes) is used. It is RECOMMENDED a client poll the resources of this function set every pollRate seconds.

Relationships

Inherits from

Descendant classes

  • No descendant classes

Associations

Source ClassCardinality SourceTarget ClassCardinality Target
DeviceStatusTemperature0..*
DeviceStatusTimeLink0..1